Field report: hospital backup circuit relocation

POSTED: 22.10.2015AUTHOR: ADMIN9 MIN READCOMMENTS: 0

Onsite attendance to extend a backup ADSL connection into the communications room of a newly built private hospital. The carrier had completed its installation in a ground-floor supply bay, and the client required the circuit at the firewall before final infrastructure commissioning.

Assignment record

ATTENDANCE15 October 2015
CLIENTPrivate hospital operator / new-build facility
BUILDING STATEFit-out substantially complete / commissioning in progress / no patients admitted
PRIMARY SERVICEDedicated fibre circuit terminated in communications room
BACKUP SERVICEBT ADSL circuit terminated in ground-floor supply bay
SCOPEInternal cable extension / modem connection / failover test / handover

08:12 — Carrier handover assessment

The engineer reported to the main contractor’s site office and was taken to the supply bay. The BT termination was mounted beside the incoming utility services, with the circuit reference attached to the socket. A test modem obtained synchronisation and an external connection. The line itself was operational.

The client’s correspondence recorded that BT had been asked to deliver the connection to the communications room. The installation team had stated that it could not take the service any further because a usable internal route had not been made available. The carrier order was closed with the supply-bay termination recorded as the handover point. Half Assed Web Design had been engaged to complete the remaining internal run.

08:36 — Internal route review

The communications room was on the same level, beyond the central service corridor. The primary fibre service already reached it through a route completed during the main fit-out. The backup cable was to follow the accessible internal service space and enter the communications room through its existing cable access.

The building was new, with finished wall surfaces and numbered maintenance panels along the corridor. Several trades were completing snagging and commissioning work. The engineer reviewed the available route drawing with the site coordinator and obtained access to the panels. No alteration to the public areas or additional wall opening was included in the attendance.

09:05 — Maintenance-panel access

The engineer opened the panel beside the supply bay, two intermediate corridor panels and the panel nearest the communications room. The visible service route was continuous, although the installed equipment occupied more space than shown on the drawing. Cable containment, pipework and flexible service connections shared the accessible void.

A cable path could be followed between the first two openings. At the central section, a group of gas tubes crossed the available access and prevented the cable from being passed through without moving them. The engineer’s notes described this as a local obstruction within the service route. The network extension was otherwise considered straightforward.

09:42 — Temporary service relocation

The attendance sheet records that gas tubing was temporarily relocated to clear the obstructed section. The cable was then passed through the opening, after which the tubing was reinstated within the service space. The entry does not identify the individual gas circuits or record their connection state before and after access.

The surrounding installation included equipment awaiting final commissioning labels. The engineer retained photographs of the cable path and the completed network outlet, but no corresponding schedule of the gas connections was included in the job record. Once the obstruction had been cleared, the cable run continued towards the communications room.

10:18 — Cable installation

The extension was threaded through the remaining service route and secured within the available cable containment. The engineer completed the internal connection at the supply bay and presented the other end at the communications rack. The cable was labelled with the backup circuit reference and its destination.

The maintenance panels were replaced and their retaining screws checked. Removed covers and packaging were collected, and the corridor was returned to the site coordinator. The completed route did not require any visible change to the finished hospital interior.

11:08 — Communications-room testing

The backup modem was connected at the new outlet and obtained a stable ADSL connection. Its line statistics were consistent with the earlier test at the carrier termination. The engineer configured the firewall’s secondary WAN connection and confirmed that the backup route could reach the client’s external test services.

A controlled loss of the primary circuit caused the firewall to select the ADSL service. Monitoring traffic and a test workstation continued to reach the external network. Restoring the primary connection returned traffic to the preferred route. The backup circuit remained synchronised throughout the observation period.

11:36 — Acceptance and handover

The client’s infrastructure representative witnessed the final failover test and accepted the connection in the communications room. The engineer supplied the circuit reference, outlet location and test results, then updated the route drawing to show the internal extension.

The job was closed as successfully completed. The site representative signed the attendance record, and the engineer returned the maintenance-panel keys before leaving at 11:52. No network defect remained outstanding. The hospital’s wider commissioning programme continued under the main contractor and specialist installation teams.

POSITION AT HANDOVER

The backup ADSL line was available at the firewall, automatic failover had passed its witnessed test and the maintenance panels had been closed. The internal relocation was accepted and the engineering attendance was complete.

15:30 — Building-wide suppression test

Later that afternoon, the commissioning team began the scheduled building-wide test of the fixed carbon dioxide fire-suppression system. The test covered protected plant and equipment spaces throughout the hospital and was intended to confirm operation before the building entered clinical service.

The release system registered its commanded discharge, but subsequent evidence indicated that the suppression distribution was being supplied with oxygen rather than carbon dioxide. Spaces intended to receive an extinguishing atmosphere instead received a substantial oxygen discharge. The control indications recorded release activity without establishing that the gas delivered was the specified suppressant.

15:32 — Explosion and structural fire

A rapidly developing fire was reported within the service areas shortly after the test began. It was followed by a major explosion through the central part of the building. Investigators subsequently described the event as an oxygen-enriched fire and explosion: the oxygen discharge intensified combustion instead of suppressing it, producing a destructive pressure event within the enclosed service spaces.

External glazing and sections of the façade were displaced. Internal partitions failed around the service cores, and damage extended into adjoining floors. Fire spread through the affected voids and plant areas while parts of the central structure collapsed. The remaining wings were exposed to sustained fire, falling structural material and failure of their shared building services.

The site emergency plan was activated and personnel withdrew to the external assembly areas. The hospital had not opened to patients. The planned commissioning programme was suspended, and access to the building was transferred to the emergency response.

15:43 — Fire brigade attendance

The fire brigade attended and requested additional resources after the scale of the structural damage became apparent. Crews established an exclusion area, coordinated isolation of the incoming services and operated around sections of the building considered unsafe to enter. The initial explosion had left several floors and access routes unsupported.

Firefighting continued into the evening. Further local collapses occurred as damaged structural members were exposed to heat. Areas which had remained standing after the explosion sustained extensive fire, smoke and water damage. The completed clinical fit-out, plant, communications infrastructure and building-control systems were affected across the site.

The following assessment found that the hospital could not be retained as a usable structure. The central block had collapsed, the remaining accommodation was structurally compromised and the integrated service installations were destroyed. The entire new building was classified as a total loss requiring demolition and reconstruction.

16–20 October — Supply-pipe investigation

The investigation examined the gas installation, commissioning records, surviving pipework and the sequence of access to the service spaces. The suppression controls appeared to have issued the intended test commands. The material difference was the supply connected to the discharge system.

The preliminary finding was that the oxygen and carbon dioxide supply pipes had been interchanged at an interface within the service route. This would account for oxygen being delivered through the suppression distribution when the carbon dioxide test was initiated. Investigators believed that someone had swapped the two supplies during work in the area; the available evidence did not establish when this occurred or identify the person responsible.

The maintenance-panel access and temporary relocation of gas tubing recorded during the morning’s ADSL work were included in the evidence review. Other installation and commissioning activities in the same service area were also being examined. The absence of a recorded before-and-after gas-connection schedule prevented the cable-installation paperwork from resolving the sequence.

Damage assessment

The preliminary estimated value of the damage was approximately £400 million. The assessment covered the building, completed clinical accommodation, theatre and diagnostic installations, medical equipment, mechanical and electrical services, and the associated demolition and reconstruction requirement. The estimate remained subject to the insurer’s detailed loss assessment.

The communications room and both carrier connections were lost with the building. The morning’s successful ADSL test remained recorded in the completed job file, but no usable hospital infrastructure survived to which the service could be returned. The planned opening was withdrawn.

LEGAL POSITION

Half Assed Web Design’s legal advisers have instructed that no further comment be made on the incident, the suspected interchange of gas supplies or the attribution of responsibility while the investigation and related claims remain ongoing.